Deflection Temperature/Vicat | Tinius Olsen https://www.tiniusolsen.com/product-category/deflection-temperature-and-vicat-testers/ Materials Testing Machines for Tensile, Compression, Impact and Hardness Testing Tue, 04 Mar 2025 05:33:20 +0000 en-US hourly 1 https://wordpress.org/?v=6.8.2 https://www.tiniusolsen.com/wp-content/uploads/2024/10/favicon-32x32-1.png Deflection Temperature/Vicat | Tinius Olsen https://www.tiniusolsen.com/product-category/deflection-temperature-and-vicat-testers/ 32 32 Model HDVT6 https://www.tiniusolsen.com/product/model-hdvt6/ https://www.tiniusolsen.com/product/model-hdvt6/#respond Tue, 18 Feb 2025 08:49:48 +0000 https://www.tiniusolsen.com/?post_type=product&p=46768

HDT – Heat Deflection (or, distortion) Temperature
DTUL – Deflection Temperature Under Load
Vicat Softening Temperature

 

HEAT DISTORTION

A specimen is placed in a frame. The frame consists of a base, which has two anvils on which the specimen is positioned. A rod is lowered on to the specimen. A mass is applied to the rod in order to apply a specified load (bending stress) to the specimen.
The entire frame is submerged in a bath containing a heat transfer medium. The temperature of the heat transfer medium is raised by a specified rate (usually 2°C/minute) until the specimen deflects (bends) a specified amount.
 
Heat distortion Standards : ASTM D648, ISO 75

 

VICAT SOFTENING TEMPERATURE

The temperature at which a specimen is penetrated a depth of 1.0 mm by a needle of defined area (1mm2) under a concentrated center load condition.
 
Vicat softening Standards : ASTM D1525, ISO 306

]]>
https://www.tiniusolsen.com/product/model-hdvt6/feed/ 0
Model HDVT3 https://www.tiniusolsen.com/product/model-hdvt3/ https://www.tiniusolsen.com/product/model-hdvt3/#respond Tue, 18 Feb 2025 07:35:05 +0000 https://www.tiniusolsen.com/?post_type=product&p=46761

HDT – Heat Deflection (or, distortion) Temperature
DTUL – Deflection Temperature Under Load
Vicat Softening Temperature

 

HEAT DISTORTION

A specimen is placed in a frame. The frame consists of a base, which has two anvils on which the specimen is positioned. A rod is lowered on to the specimen. A mass is applied to the rod in order to apply a specified load (bending stress) to the specimen.
The entire frame is submerged in a bath containing a heat transfer medium. The temperature of the heat transfer medium is raised by a specified rate (usually 2°C/minute) until the specimen deflects (bends) a specified amount.
 
Heat distortion Standards : ASTM D648, ISO 75

 

VICAT SOFTENING TEMPERATURE

The temperature at which a specimen is penetrated a depth of 1.0 mm by a needle of defined area (1mm2) under a concentrated center load condition.
 
Vicat softening Standards : ASTM D1525, ISO 306

]]>